High-performance liquid chromatography determination of anilines with fluorescent detection and pre-column derivatization

Salma M Z Al-Kindy, Azza Al-Kalbani, Ahmed F. Al-Harasi, FakhrEldin O. Suliman, Haider J. Al-Lawati, Abdalla Al-Hamadi

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A simple, sensitive, and rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of anilines in water is proposed. The use of 2,7-diethylamino-2-oxo-2H-chromen-3-yl-benzothiazole-6- sulfonylchloride (coumarin 6-SO2Cl) as a fluorigenic-labeling reagent was investigated. The label reacted with aniline within 30 min under mild conditions (ambient temperature, pH 9.0) to give sulfonamides that were separated by RP-HPLC employing fluorescence detection with an excitation wavelength of 470 nm and an emission wavelength of 520 nm. The optimum conditions for fluorescence, derivatization, and chromatographic separation were established. The calibration curves were linear for the range 0-800 ppb. The proposed method was applied for the determination of anilines in spiked drinking water samples and irrigation water samples with recoveries of 90.0-103.9% and relative standard deviations of 1.2-4.7%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of aniline in real samples.

Original languageEnglish
Pages (from-to)48-59
Number of pages12
JournalInstrumentation Science and Technology
Volume41
Issue number1
DOIs
Publication statusPublished - Jan 1 2013

Fingerprint

Aniline Compounds
liquid chromatography
High performance liquid chromatography
Aniline
aniline
Fluorescence
Wavelength
Water
Sulfonamides
fluorescence
Irrigation
Drinking Water
Labeling
wavelength
Labels
Calibration
water
Recovery
irrigation
drinking

Keywords

  • anilines
  • coumarin 6-SOCL
  • fluorescence detection
  • high-performance liquid chromatography (HPLC)
  • pre-column derivatization

ASJC Scopus subject areas

  • Instrumentation
  • Chemical Engineering(all)
  • Environmental Science(all)

Cite this

High-performance liquid chromatography determination of anilines with fluorescent detection and pre-column derivatization. / Al-Kindy, Salma M Z; Al-Kalbani, Azza; Al-Harasi, Ahmed F.; Suliman, FakhrEldin O.; Al-Lawati, Haider J.; Al-Hamadi, Abdalla.

In: Instrumentation Science and Technology, Vol. 41, No. 1, 01.01.2013, p. 48-59.

Research output: Contribution to journalArticle

@article{90a699629bf74f7d838ac647fddf819c,
title = "High-performance liquid chromatography determination of anilines with fluorescent detection and pre-column derivatization",
abstract = "A simple, sensitive, and rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of anilines in water is proposed. The use of 2,7-diethylamino-2-oxo-2H-chromen-3-yl-benzothiazole-6- sulfonylchloride (coumarin 6-SO2Cl) as a fluorigenic-labeling reagent was investigated. The label reacted with aniline within 30 min under mild conditions (ambient temperature, pH 9.0) to give sulfonamides that were separated by RP-HPLC employing fluorescence detection with an excitation wavelength of 470 nm and an emission wavelength of 520 nm. The optimum conditions for fluorescence, derivatization, and chromatographic separation were established. The calibration curves were linear for the range 0-800 ppb. The proposed method was applied for the determination of anilines in spiked drinking water samples and irrigation water samples with recoveries of 90.0-103.9{\%} and relative standard deviations of 1.2-4.7{\%}, respectively. This method showed good accuracy and repeatability that can be used for the quantification of aniline in real samples.",
keywords = "anilines, coumarin 6-SOCL, fluorescence detection, high-performance liquid chromatography (HPLC), pre-column derivatization",
author = "Al-Kindy, {Salma M Z} and Azza Al-Kalbani and Al-Harasi, {Ahmed F.} and Suliman, {FakhrEldin O.} and Al-Lawati, {Haider J.} and Abdalla Al-Hamadi",
year = "2013",
month = "1",
day = "1",
doi = "10.1080/10739149.2012.721108",
language = "English",
volume = "41",
pages = "48--59",
journal = "Instrumentation Science and Technology",
issn = "1073-9149",
publisher = "Taylor and Francis Ltd.",
number = "1",

}

TY - JOUR

T1 - High-performance liquid chromatography determination of anilines with fluorescent detection and pre-column derivatization

AU - Al-Kindy, Salma M Z

AU - Al-Kalbani, Azza

AU - Al-Harasi, Ahmed F.

AU - Suliman, FakhrEldin O.

AU - Al-Lawati, Haider J.

AU - Al-Hamadi, Abdalla

PY - 2013/1/1

Y1 - 2013/1/1

N2 - A simple, sensitive, and rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of anilines in water is proposed. The use of 2,7-diethylamino-2-oxo-2H-chromen-3-yl-benzothiazole-6- sulfonylchloride (coumarin 6-SO2Cl) as a fluorigenic-labeling reagent was investigated. The label reacted with aniline within 30 min under mild conditions (ambient temperature, pH 9.0) to give sulfonamides that were separated by RP-HPLC employing fluorescence detection with an excitation wavelength of 470 nm and an emission wavelength of 520 nm. The optimum conditions for fluorescence, derivatization, and chromatographic separation were established. The calibration curves were linear for the range 0-800 ppb. The proposed method was applied for the determination of anilines in spiked drinking water samples and irrigation water samples with recoveries of 90.0-103.9% and relative standard deviations of 1.2-4.7%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of aniline in real samples.

AB - A simple, sensitive, and rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of anilines in water is proposed. The use of 2,7-diethylamino-2-oxo-2H-chromen-3-yl-benzothiazole-6- sulfonylchloride (coumarin 6-SO2Cl) as a fluorigenic-labeling reagent was investigated. The label reacted with aniline within 30 min under mild conditions (ambient temperature, pH 9.0) to give sulfonamides that were separated by RP-HPLC employing fluorescence detection with an excitation wavelength of 470 nm and an emission wavelength of 520 nm. The optimum conditions for fluorescence, derivatization, and chromatographic separation were established. The calibration curves were linear for the range 0-800 ppb. The proposed method was applied for the determination of anilines in spiked drinking water samples and irrigation water samples with recoveries of 90.0-103.9% and relative standard deviations of 1.2-4.7%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of aniline in real samples.

KW - anilines

KW - coumarin 6-SOCL

KW - fluorescence detection

KW - high-performance liquid chromatography (HPLC)

KW - pre-column derivatization

UR - http://www.scopus.com/inward/record.url?scp=84873684892&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84873684892&partnerID=8YFLogxK

U2 - 10.1080/10739149.2012.721108

DO - 10.1080/10739149.2012.721108

M3 - Article

VL - 41

SP - 48

EP - 59

JO - Instrumentation Science and Technology

JF - Instrumentation Science and Technology

SN - 1073-9149

IS - 1

ER -