The Performance of Strip Footing Resting on Geogrid-Reinforced Dune Sand

Research output: Contribution to journalArticle

Abstract

Laboratory model tests were carried out to study the behavior of strip footing resting on a geogrids-reinforced dune sand. The tests were performed on a rigid steel tank having glass side with inner dimensions of 1 m by 0.64 m by 0.23 m. Footings were placed at different depths from the surface of sand. Geogrids were placed at different depths below the footing starting at 0.25B to 1.25B. The sand was placed in the tank using raining method. The use of geogrids improved the bearing capacity of strip footings by a factor of up to 4 times. The improvement depends on depth of the footing, the depth of the geogrids below the footing and the number of the geogrids layers. For two layers of geogrids the highest improvement is when the depth of first reinforcement below the footing is between 0.25 to 0.5B, the spacing (h) is between 0.25 to 0.5B and the overall depth of the reinforcements (dr) is about 0.5 to 0.75B. The geogrids modified the load-settlement curve for the footing by increasing the strains at failure to up to three times that of unreinforced sand. This means with geogrids the footing will undergo more elastic settlements before failure.

Original languageEnglish
Pages (from-to)106-113
Number of pages8
JournalGeotechnical Special Publication
Volume2016-January
Issue number261 GSP
DOIs
Publication statusPublished - 2016

Fingerprint

footing
dune
Sand
Reinforcement
Steel tanks
Bearing capacity
reinforcement
sand
Glass
geogrid
bearing capacity
model test
spacing
glass
steel

ASJC Scopus subject areas

  • Architecture
  • Civil and Structural Engineering
  • Building and Construction
  • Geotechnical Engineering and Engineering Geology

Cite this

The Performance of Strip Footing Resting on Geogrid-Reinforced Dune Sand. / Mohamedzein, Yahia E.A.; Al-Aghbari, Mohammed Y.

In: Geotechnical Special Publication, Vol. 2016-January, No. 261 GSP, 2016, p. 106-113.

Research output: Contribution to journalArticle

@article{00b6a1597b0b4655a4d3c7b0a461566a,
title = "The Performance of Strip Footing Resting on Geogrid-Reinforced Dune Sand",
abstract = "Laboratory model tests were carried out to study the behavior of strip footing resting on a geogrids-reinforced dune sand. The tests were performed on a rigid steel tank having glass side with inner dimensions of 1 m by 0.64 m by 0.23 m. Footings were placed at different depths from the surface of sand. Geogrids were placed at different depths below the footing starting at 0.25B to 1.25B. The sand was placed in the tank using raining method. The use of geogrids improved the bearing capacity of strip footings by a factor of up to 4 times. The improvement depends on depth of the footing, the depth of the geogrids below the footing and the number of the geogrids layers. For two layers of geogrids the highest improvement is when the depth of first reinforcement below the footing is between 0.25 to 0.5B, the spacing (h) is between 0.25 to 0.5B and the overall depth of the reinforcements (dr) is about 0.5 to 0.75B. The geogrids modified the load-settlement curve for the footing by increasing the strains at failure to up to three times that of unreinforced sand. This means with geogrids the footing will undergo more elastic settlements before failure.",
author = "Mohamedzein, {Yahia E.A.} and Al-Aghbari, {Mohammed Y.}",
year = "2016",
doi = "10.1061/9780784480045.014",
language = "English",
volume = "2016-January",
pages = "106--113",
journal = "Geotechnical Special Publication",
issn = "0895-0563",
publisher = "American Society of Civil Engineers (ASCE)",
number = "261 GSP",

}

TY - JOUR

T1 - The Performance of Strip Footing Resting on Geogrid-Reinforced Dune Sand

AU - Mohamedzein, Yahia E.A.

AU - Al-Aghbari, Mohammed Y.

PY - 2016

Y1 - 2016

N2 - Laboratory model tests were carried out to study the behavior of strip footing resting on a geogrids-reinforced dune sand. The tests were performed on a rigid steel tank having glass side with inner dimensions of 1 m by 0.64 m by 0.23 m. Footings were placed at different depths from the surface of sand. Geogrids were placed at different depths below the footing starting at 0.25B to 1.25B. The sand was placed in the tank using raining method. The use of geogrids improved the bearing capacity of strip footings by a factor of up to 4 times. The improvement depends on depth of the footing, the depth of the geogrids below the footing and the number of the geogrids layers. For two layers of geogrids the highest improvement is when the depth of first reinforcement below the footing is between 0.25 to 0.5B, the spacing (h) is between 0.25 to 0.5B and the overall depth of the reinforcements (dr) is about 0.5 to 0.75B. The geogrids modified the load-settlement curve for the footing by increasing the strains at failure to up to three times that of unreinforced sand. This means with geogrids the footing will undergo more elastic settlements before failure.

AB - Laboratory model tests were carried out to study the behavior of strip footing resting on a geogrids-reinforced dune sand. The tests were performed on a rigid steel tank having glass side with inner dimensions of 1 m by 0.64 m by 0.23 m. Footings were placed at different depths from the surface of sand. Geogrids were placed at different depths below the footing starting at 0.25B to 1.25B. The sand was placed in the tank using raining method. The use of geogrids improved the bearing capacity of strip footings by a factor of up to 4 times. The improvement depends on depth of the footing, the depth of the geogrids below the footing and the number of the geogrids layers. For two layers of geogrids the highest improvement is when the depth of first reinforcement below the footing is between 0.25 to 0.5B, the spacing (h) is between 0.25 to 0.5B and the overall depth of the reinforcements (dr) is about 0.5 to 0.75B. The geogrids modified the load-settlement curve for the footing by increasing the strains at failure to up to three times that of unreinforced sand. This means with geogrids the footing will undergo more elastic settlements before failure.

UR - http://www.scopus.com/inward/record.url?scp=84983551594&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84983551594&partnerID=8YFLogxK

U2 - 10.1061/9780784480045.014

DO - 10.1061/9780784480045.014

M3 - Article

AN - SCOPUS:84983551594

VL - 2016-January

SP - 106

EP - 113

JO - Geotechnical Special Publication

JF - Geotechnical Special Publication

SN - 0895-0563

IS - 261 GSP

ER -