Estimation of ion adsorption using iterative analytical model in capacitive deionization process

Muhammad Shafiq, Karthik Laxman, Joydeep Dutta

Research output: Contribution to journalArticle

Abstract

Capacitive deionization (CDI) is an upcoming technique that can replace existing processes for removing and recuperating metal ions from dilute industrial waste waters. CDI removes ions via electrosorption on to its electrode surfaces, the efficiency of which is a function of CDI electrode properties that progressively change during continued operation. As such a need exists to develop a model to predict CDI performance over elongated periods which is independent of electrode properties and has negligible error values. By applying a first order non-linear dynamic model (FONDM) with inputs independent of the electrode characteristics, we propose a universal model that can predict CDI ion adsorption capacity with changes in applied potential, flow rate and electrolyte temperature to within 5% of the experimentally obtained results. The model was verified using activated carbon cloth (ACC) as a test electrode and aqueous sodium chloride solution as electrolyte, with a good prediction for ion electrosorption efficiency and time dependent electrosorption dynamics. The simplicity of the model makes it easy to adapt for various applications and in the development of intelligent control systems for CDI units in practical settings.

Original languageEnglish
Pages (from-to)75-82
Number of pages8
JournalDesalination and Water Treatment
Volume116
DOIs
Publication statusPublished - Jun 1 2018

Fingerprint

Analytical models
electrode
adsorption
Adsorption
Electrodes
ion
Ions
electrolyte
Electrolytes
potential flow
Potential flow
Intelligent control
Industrial wastes
Sodium chloride
sodium chloride
Activated carbon
activated carbon
Metal ions
control system
Dynamic models

Keywords

  • Activated carbon cloth
  • Analytical model
  • Capacitive deionization (CDI)
  • Electrosorption
  • Ion adsorption

ASJC Scopus subject areas

  • Water Science and Technology
  • Ocean Engineering
  • Pollution

Cite this

Estimation of ion adsorption using iterative analytical model in capacitive deionization process. / Shafiq, Muhammad; Laxman, Karthik; Dutta, Joydeep.

In: Desalination and Water Treatment, Vol. 116, 01.06.2018, p. 75-82.

Research output: Contribution to journalArticle

@article{4c19492a5247435fa9b70d6d5dc6f91d,
title = "Estimation of ion adsorption using iterative analytical model in capacitive deionization process",
abstract = "Capacitive deionization (CDI) is an upcoming technique that can replace existing processes for removing and recuperating metal ions from dilute industrial waste waters. CDI removes ions via electrosorption on to its electrode surfaces, the efficiency of which is a function of CDI electrode properties that progressively change during continued operation. As such a need exists to develop a model to predict CDI performance over elongated periods which is independent of electrode properties and has negligible error values. By applying a first order non-linear dynamic model (FONDM) with inputs independent of the electrode characteristics, we propose a universal model that can predict CDI ion adsorption capacity with changes in applied potential, flow rate and electrolyte temperature to within 5{\%} of the experimentally obtained results. The model was verified using activated carbon cloth (ACC) as a test electrode and aqueous sodium chloride solution as electrolyte, with a good prediction for ion electrosorption efficiency and time dependent electrosorption dynamics. The simplicity of the model makes it easy to adapt for various applications and in the development of intelligent control systems for CDI units in practical settings.",
keywords = "Activated carbon cloth, Analytical model, Capacitive deionization (CDI), Electrosorption, Ion adsorption",
author = "Muhammad Shafiq and Karthik Laxman and Joydeep Dutta",
year = "2018",
month = "6",
day = "1",
doi = "10.5004/dwt.2018.22322",
language = "English",
volume = "116",
pages = "75--82",
journal = "Desalination and Water Treatment",
issn = "1944-3994",
publisher = "Taylor and Francis Ltd.",

}

TY - JOUR

T1 - Estimation of ion adsorption using iterative analytical model in capacitive deionization process

AU - Shafiq, Muhammad

AU - Laxman, Karthik

AU - Dutta, Joydeep

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Capacitive deionization (CDI) is an upcoming technique that can replace existing processes for removing and recuperating metal ions from dilute industrial waste waters. CDI removes ions via electrosorption on to its electrode surfaces, the efficiency of which is a function of CDI electrode properties that progressively change during continued operation. As such a need exists to develop a model to predict CDI performance over elongated periods which is independent of electrode properties and has negligible error values. By applying a first order non-linear dynamic model (FONDM) with inputs independent of the electrode characteristics, we propose a universal model that can predict CDI ion adsorption capacity with changes in applied potential, flow rate and electrolyte temperature to within 5% of the experimentally obtained results. The model was verified using activated carbon cloth (ACC) as a test electrode and aqueous sodium chloride solution as electrolyte, with a good prediction for ion electrosorption efficiency and time dependent electrosorption dynamics. The simplicity of the model makes it easy to adapt for various applications and in the development of intelligent control systems for CDI units in practical settings.

AB - Capacitive deionization (CDI) is an upcoming technique that can replace existing processes for removing and recuperating metal ions from dilute industrial waste waters. CDI removes ions via electrosorption on to its electrode surfaces, the efficiency of which is a function of CDI electrode properties that progressively change during continued operation. As such a need exists to develop a model to predict CDI performance over elongated periods which is independent of electrode properties and has negligible error values. By applying a first order non-linear dynamic model (FONDM) with inputs independent of the electrode characteristics, we propose a universal model that can predict CDI ion adsorption capacity with changes in applied potential, flow rate and electrolyte temperature to within 5% of the experimentally obtained results. The model was verified using activated carbon cloth (ACC) as a test electrode and aqueous sodium chloride solution as electrolyte, with a good prediction for ion electrosorption efficiency and time dependent electrosorption dynamics. The simplicity of the model makes it easy to adapt for various applications and in the development of intelligent control systems for CDI units in practical settings.

KW - Activated carbon cloth

KW - Analytical model

KW - Capacitive deionization (CDI)

KW - Electrosorption

KW - Ion adsorption

UR - http://www.scopus.com/inward/record.url?scp=85054531137&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85054531137&partnerID=8YFLogxK

U2 - 10.5004/dwt.2018.22322

DO - 10.5004/dwt.2018.22322

M3 - Article

VL - 116

SP - 75

EP - 82

JO - Desalination and Water Treatment

JF - Desalination and Water Treatment

SN - 1944-3994