Longevity studies on the CMS-RPC system

A. Gelmi*, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Lohan, G. Sultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. PetrovS. J. Qian, D. Han, W. Yi, C. Avila, A. Cabrera, C. Carrillo, M. Segura, S. Aly, Y. Assran, A. Mahrous, A. Mohamed, C. Combaret, M. Gouzevitch, G. Grenier, F. Lagarde, I. B. Laktineh, H. Mathez, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, L. M. Pant, V. Bhatnagar, R. Gupta, R. Kumari, M. Manisha, J. B. Singh, V. Amoozegar, B. Boghrati, H. Ghasemy, S. Malmir, M. Mohammadi Najafabadi, M. Abbrescia, G. Iaselli, S. Lezki, G. Pugliese, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, S. Buontempo, A. Crescenzo, G. Galati, F. Fienga, I. Orso, L. Lista, S. Meola, P. Paolucci, E. Voevodina, A. Braghieri, P. Montagna, M. Ressegotti, C. Riccardi, P. Salvini, P. Vitulo, S. W. Cho, S. Y. Choi, B. Hong, K. S. Lee, J. H. Lim, S. K. Park, J. Goh, T. J. Kim, S. Carrillo Moreno, O. Miguel Colin, F. Vazquez Valencia, S. Carpinteyro Bernardino, J. Eysermans, I. Pedraza, C. Uribe Estrada, R. Reyes-Almanza, M. C. Duran-Osuna, M. Ramirez-Garcia, G. Ramirez-Sanchez, A. Sanchez-Hernandez, R. I. Rabadan-Trejo, H. Castilla-Valdez, A. Radi, H. Hoorani, S. Muhammad, M. A. Shah, I. Crotty

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

1 اقتباس (Scopus)

ملخص

In the next decades, the Large Hadron Collider (LHC) will run at very high luminosity (HL-LHC) 5×1034 cm-2s-1, factor five more than the nominal LHC luminosity. During this period the CMS RPC system will be subjected to high background rates which could affect the performance by inducing aging effects. A dedicated longevity program to qualify the present RPC system for the HL-LHC running period is ongoing. At the CERN Gamma Irradiation Facility (GIF++) four RPC detectors, from the spare production, are exposed to an intense gamma radiation for a dose equivalent to the one expected at the HL-LHC . The main detector parameters are under monitoring as a function of the integrated charge and the performance is studied with a muon beam. Preliminary results of the study after having collected 34% of the expected integrated charge will be presented.

اللغة الأصليةEnglish
رقم المقالC05012
دوريةJournal of Instrumentation
مستوى الصوت14
رقم الإصدار5
المعرِّفات الرقمية للأشياء
حالة النشرPublished - مايو 14 2019

ASJC Scopus subject areas

  • ???subjectarea.asjc.3100.3105???
  • ???subjectarea.asjc.2600.2610???

قم بذكر هذا