Dispersed Phase Holdup in a Tall and Low Plate Free Area Liquid Pulsed Sieve-Plate Extraction Column

S. Y. Khawaja, M. R. Usman, S. Khan, W. Afzal, N. A. Akhtar

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

10 اقتباسات (Scopus)

ملخص

Dispersed phase holdup is studied in a tall and low plate free area pulsed sieve-plate extraction column. The 5.0 cm internal diameter column consists of 80 number of plates with percent free area of 13.5. The effects of pulse velocity (product of amplitude and frequency), superficial phase velocities, and solute addition are studied for five liquid-liquid systems with a wide range of interfacial tensions. The experimental holdup data is tested against the most widely recommended correlations and a new correlation has been developed that best fits the data.

اللغة الأصليةEnglish
الصفحات (من إلى)175-182
عدد الصفحات8
دوريةSeparation Science and Technology (Philadelphia)
مستوى الصوت48
رقم الإصدار1
المعرِّفات الرقمية للأشياء
حالة النشرPublished - يناير 2013
منشور خارجيًانعم

ASJC Scopus subject areas

  • ???subjectarea.asjc.1600.1600???
  • ???subjectarea.asjc.1500.1500???
  • ???subjectarea.asjc.1500.1508???
  • ???subjectarea.asjc.1500.1506???

بصمة

أدرس بدقة موضوعات البحث “Dispersed Phase Holdup in a Tall and Low Plate Free Area Liquid Pulsed Sieve-Plate Extraction Column'. فهما يشكلان معًا بصمة فريدة.