Sequential Injection Method for the Determination of Oxprenolol in Pharmaceutical Products Using Chemometric Methods of Optimization

F. E O Suliman, Salah M. Sultan

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

A sequential injection (SI) spectrophotometric method for the determination of oxprenolol in pharmaceutical products was developed. The method is based on the oxidation of oxprenolol on-line with Ce(IV) in sulfuric acid medium and the subsequent monitoring of the absorbance of the oxidized form of the drug at 480 nm. The procedure was optimized by the orthogonal array design at two and four levels. The factors included in the optimization were Ce(IV) concentration, sulfuric acid concentration, and the stop time of the composite zone at the reaction coil. The optimized SI system with a linear dynamic range of 50-400 ppm was found to be suitable for the assay of oxprenolol in pharmaceutical products.

Original languageEnglish
Pages (from-to)320-327
Number of pages8
JournalMicrochemical Journal
Volume57
Issue number3
Publication statusPublished - Nov 1997

Fingerprint

Oxprenolol
Pharmaceutical Preparations
Assays
Oxidation
Monitoring
Composite materials
sulfuric acid

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Sequential Injection Method for the Determination of Oxprenolol in Pharmaceutical Products Using Chemometric Methods of Optimization. / Suliman, F. E O; Sultan, Salah M.

In: Microchemical Journal, Vol. 57, No. 3, 11.1997, p. 320-327.

Research output: Contribution to journalArticle

@article{d2cf109f061d4e7db3a17de14eab001c,
title = "Sequential Injection Method for the Determination of Oxprenolol in Pharmaceutical Products Using Chemometric Methods of Optimization",
abstract = "A sequential injection (SI) spectrophotometric method for the determination of oxprenolol in pharmaceutical products was developed. The method is based on the oxidation of oxprenolol on-line with Ce(IV) in sulfuric acid medium and the subsequent monitoring of the absorbance of the oxidized form of the drug at 480 nm. The procedure was optimized by the orthogonal array design at two and four levels. The factors included in the optimization were Ce(IV) concentration, sulfuric acid concentration, and the stop time of the composite zone at the reaction coil. The optimized SI system with a linear dynamic range of 50-400 ppm was found to be suitable for the assay of oxprenolol in pharmaceutical products.",
author = "Suliman, {F. E O} and Sultan, {Salah M.}",
year = "1997",
month = "11",
language = "English",
volume = "57",
pages = "320--327",
journal = "Microchemical Journal",
issn = "0026-265X",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Sequential Injection Method for the Determination of Oxprenolol in Pharmaceutical Products Using Chemometric Methods of Optimization

AU - Suliman, F. E O

AU - Sultan, Salah M.

PY - 1997/11

Y1 - 1997/11

N2 - A sequential injection (SI) spectrophotometric method for the determination of oxprenolol in pharmaceutical products was developed. The method is based on the oxidation of oxprenolol on-line with Ce(IV) in sulfuric acid medium and the subsequent monitoring of the absorbance of the oxidized form of the drug at 480 nm. The procedure was optimized by the orthogonal array design at two and four levels. The factors included in the optimization were Ce(IV) concentration, sulfuric acid concentration, and the stop time of the composite zone at the reaction coil. The optimized SI system with a linear dynamic range of 50-400 ppm was found to be suitable for the assay of oxprenolol in pharmaceutical products.

AB - A sequential injection (SI) spectrophotometric method for the determination of oxprenolol in pharmaceutical products was developed. The method is based on the oxidation of oxprenolol on-line with Ce(IV) in sulfuric acid medium and the subsequent monitoring of the absorbance of the oxidized form of the drug at 480 nm. The procedure was optimized by the orthogonal array design at two and four levels. The factors included in the optimization were Ce(IV) concentration, sulfuric acid concentration, and the stop time of the composite zone at the reaction coil. The optimized SI system with a linear dynamic range of 50-400 ppm was found to be suitable for the assay of oxprenolol in pharmaceutical products.

UR - http://www.scopus.com/inward/record.url?scp=0000448089&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0000448089&partnerID=8YFLogxK

M3 - Article

VL - 57

SP - 320

EP - 327

JO - Microchemical Journal

JF - Microchemical Journal

SN - 0026-265X

IS - 3

ER -