Moisture adsorption isotherms of microwave-baked Madeira cake

Ala'a H. Al-Muhtaseb, Muhanned A. Hararah, E. K. Megahey, W. A M McMinn, T. R A Magee

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Adsorption isotherms of microwave-baked Madeira cake, flour and sugar were determined using a standard static gravimetric method within the temperature range 5-60 °C and relative humidity range of 0.04-0.96. Microwave-baked Madeira cake and sugar samples exhibited Type III isotherm behaviour, whereas flour exhibited Type II characteristics, with the sorption capacity decreasing with increasing temperature for Madeira cake and flour. Conversely, the equilibrium moisture content of the sugar samples increased with increasing temperature at water activity values greater than 0.88. Experimental data obtained were fitted to several isotherm models and their goodness-of-fit evaluated in terms of mean relative error (MRE), standard error of estimate (SEE) and residual sum-of-squares (RSS). Nonlinear least square regression software was used to evaluate the models parameters. The Ferro-Fontan model provided the best description of the experimental sorption behaviour of microwave-baked Madeira cake and flour. The net isosteric heat of sorption was determined from the equilibrium adsorption data, using the Clausius-Clapeyron equation. The heat of adsorption decreased with increase in moisture content and approached a constant value. It showed a power law relationship with moisture content for microwave-baked Madeira cake and exponential relationship for flour.

Original languageEnglish
Pages (from-to)1042-1049
Number of pages8
JournalLWT - Food Science and Technology
Volume43
Issue number7
DOIs
Publication statusPublished - Sep 2010

Fingerprint

Flour
Microwaves
Adsorption
flour
adsorption
sorption
sugars
water content
Temperature
Hot Temperature
heat
temperature
Humidity
Least-Squares Analysis
water activity
least squares
relative humidity
Software
sampling
Water

Keywords

  • Flour
  • Isotherm models
  • Microwave-baked Madeira cake
  • Net isosteric heat of sorption
  • Sorption isotherm
  • Standard static gravimetric method
  • Sugar

ASJC Scopus subject areas

  • Food Science

Cite this

Moisture adsorption isotherms of microwave-baked Madeira cake. / Al-Muhtaseb, Ala'a H.; Hararah, Muhanned A.; Megahey, E. K.; McMinn, W. A M; Magee, T. R A.

In: LWT - Food Science and Technology, Vol. 43, No. 7, 09.2010, p. 1042-1049.

Research output: Contribution to journalArticle

Al-Muhtaseb, Ala'a H. ; Hararah, Muhanned A. ; Megahey, E. K. ; McMinn, W. A M ; Magee, T. R A. / Moisture adsorption isotherms of microwave-baked Madeira cake. In: LWT - Food Science and Technology. 2010 ; Vol. 43, No. 7. pp. 1042-1049.
@article{146d883114c545ccae1d3746be2f700d,
title = "Moisture adsorption isotherms of microwave-baked Madeira cake",
abstract = "Adsorption isotherms of microwave-baked Madeira cake, flour and sugar were determined using a standard static gravimetric method within the temperature range 5-60 °C and relative humidity range of 0.04-0.96. Microwave-baked Madeira cake and sugar samples exhibited Type III isotherm behaviour, whereas flour exhibited Type II characteristics, with the sorption capacity decreasing with increasing temperature for Madeira cake and flour. Conversely, the equilibrium moisture content of the sugar samples increased with increasing temperature at water activity values greater than 0.88. Experimental data obtained were fitted to several isotherm models and their goodness-of-fit evaluated in terms of mean relative error (MRE), standard error of estimate (SEE) and residual sum-of-squares (RSS). Nonlinear least square regression software was used to evaluate the models parameters. The Ferro-Fontan model provided the best description of the experimental sorption behaviour of microwave-baked Madeira cake and flour. The net isosteric heat of sorption was determined from the equilibrium adsorption data, using the Clausius-Clapeyron equation. The heat of adsorption decreased with increase in moisture content and approached a constant value. It showed a power law relationship with moisture content for microwave-baked Madeira cake and exponential relationship for flour.",
keywords = "Flour, Isotherm models, Microwave-baked Madeira cake, Net isosteric heat of sorption, Sorption isotherm, Standard static gravimetric method, Sugar",
author = "Al-Muhtaseb, {Ala'a H.} and Hararah, {Muhanned A.} and Megahey, {E. K.} and McMinn, {W. A M} and Magee, {T. R A}",
year = "2010",
month = "9",
doi = "10.1016/j.lwt.2010.01.003",
language = "English",
volume = "43",
pages = "1042--1049",
journal = "LWT - Food Science and Technology",
issn = "0023-6438",
publisher = "Academic Press Inc.",
number = "7",

}

TY - JOUR

T1 - Moisture adsorption isotherms of microwave-baked Madeira cake

AU - Al-Muhtaseb, Ala'a H.

AU - Hararah, Muhanned A.

AU - Megahey, E. K.

AU - McMinn, W. A M

AU - Magee, T. R A

PY - 2010/9

Y1 - 2010/9

N2 - Adsorption isotherms of microwave-baked Madeira cake, flour and sugar were determined using a standard static gravimetric method within the temperature range 5-60 °C and relative humidity range of 0.04-0.96. Microwave-baked Madeira cake and sugar samples exhibited Type III isotherm behaviour, whereas flour exhibited Type II characteristics, with the sorption capacity decreasing with increasing temperature for Madeira cake and flour. Conversely, the equilibrium moisture content of the sugar samples increased with increasing temperature at water activity values greater than 0.88. Experimental data obtained were fitted to several isotherm models and their goodness-of-fit evaluated in terms of mean relative error (MRE), standard error of estimate (SEE) and residual sum-of-squares (RSS). Nonlinear least square regression software was used to evaluate the models parameters. The Ferro-Fontan model provided the best description of the experimental sorption behaviour of microwave-baked Madeira cake and flour. The net isosteric heat of sorption was determined from the equilibrium adsorption data, using the Clausius-Clapeyron equation. The heat of adsorption decreased with increase in moisture content and approached a constant value. It showed a power law relationship with moisture content for microwave-baked Madeira cake and exponential relationship for flour.

AB - Adsorption isotherms of microwave-baked Madeira cake, flour and sugar were determined using a standard static gravimetric method within the temperature range 5-60 °C and relative humidity range of 0.04-0.96. Microwave-baked Madeira cake and sugar samples exhibited Type III isotherm behaviour, whereas flour exhibited Type II characteristics, with the sorption capacity decreasing with increasing temperature for Madeira cake and flour. Conversely, the equilibrium moisture content of the sugar samples increased with increasing temperature at water activity values greater than 0.88. Experimental data obtained were fitted to several isotherm models and their goodness-of-fit evaluated in terms of mean relative error (MRE), standard error of estimate (SEE) and residual sum-of-squares (RSS). Nonlinear least square regression software was used to evaluate the models parameters. The Ferro-Fontan model provided the best description of the experimental sorption behaviour of microwave-baked Madeira cake and flour. The net isosteric heat of sorption was determined from the equilibrium adsorption data, using the Clausius-Clapeyron equation. The heat of adsorption decreased with increase in moisture content and approached a constant value. It showed a power law relationship with moisture content for microwave-baked Madeira cake and exponential relationship for flour.

KW - Flour

KW - Isotherm models

KW - Microwave-baked Madeira cake

KW - Net isosteric heat of sorption

KW - Sorption isotherm

KW - Standard static gravimetric method

KW - Sugar

UR - http://www.scopus.com/inward/record.url?scp=79955946607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79955946607&partnerID=8YFLogxK

U2 - 10.1016/j.lwt.2010.01.003

DO - 10.1016/j.lwt.2010.01.003

M3 - Article

AN - SCOPUS:79955946607

VL - 43

SP - 1042

EP - 1049

JO - LWT - Food Science and Technology

JF - LWT - Food Science and Technology

SN - 0023-6438

IS - 7

ER -