Measurements and evaluation of harmonics in HV networks - Oman MIS case study

M. H. Albadi, A. S. Al Hinai, A. H. Al-Badi, M. S. Al Riyami, S. M. Al Hinai, R. S. Al Abri

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

This paper presents a case study about the impacts of industrial loads on power quality. A review of harmonics causes, negative impacts, mitigation techniques, quantification indices and limits are presented. Moreover, harmonics measurements at three grid station that supply the three main industrial areas located in the Main Interconnected System (MIS) of Oman are conducted. Measurement results are compared with limits specified by national and international standards.

Original languageEnglish
Title of host publication2013 7th IEEE GCC Conference and Exhibition, GCC 2013
Pages49-53
Number of pages5
DOIs
Publication statusPublished - 2013
Event2013 7th IEEE GCC Conference and Exhibition, GCC 2013 - Doha, Qatar
Duration: Nov 17 2013Nov 20 2013

Other

Other2013 7th IEEE GCC Conference and Exhibition, GCC 2013
CountryQatar
CityDoha
Period11/17/1311/20/13

Fingerprint

Large scale systems
Power quality

Keywords

  • Harmonics
  • Measurements
  • Power Quality
  • Standards

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Albadi, M. H., Al Hinai, A. S., Al-Badi, A. H., Al Riyami, M. S., Al Hinai, S. M., & Al Abri, R. S. (2013). Measurements and evaluation of harmonics in HV networks - Oman MIS case study. In 2013 7th IEEE GCC Conference and Exhibition, GCC 2013 (pp. 49-53). [6705747] https://doi.org/10.1109/IEEEGCC.2013.6705747

Measurements and evaluation of harmonics in HV networks - Oman MIS case study. / Albadi, M. H.; Al Hinai, A. S.; Al-Badi, A. H.; Al Riyami, M. S.; Al Hinai, S. M.; Al Abri, R. S.

2013 7th IEEE GCC Conference and Exhibition, GCC 2013. 2013. p. 49-53 6705747.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Albadi, MH, Al Hinai, AS, Al-Badi, AH, Al Riyami, MS, Al Hinai, SM & Al Abri, RS 2013, Measurements and evaluation of harmonics in HV networks - Oman MIS case study. in 2013 7th IEEE GCC Conference and Exhibition, GCC 2013., 6705747, pp. 49-53, 2013 7th IEEE GCC Conference and Exhibition, GCC 2013, Doha, Qatar, 11/17/13. https://doi.org/10.1109/IEEEGCC.2013.6705747
Albadi MH, Al Hinai AS, Al-Badi AH, Al Riyami MS, Al Hinai SM, Al Abri RS. Measurements and evaluation of harmonics in HV networks - Oman MIS case study. In 2013 7th IEEE GCC Conference and Exhibition, GCC 2013. 2013. p. 49-53. 6705747 https://doi.org/10.1109/IEEEGCC.2013.6705747
Albadi, M. H. ; Al Hinai, A. S. ; Al-Badi, A. H. ; Al Riyami, M. S. ; Al Hinai, S. M. ; Al Abri, R. S. / Measurements and evaluation of harmonics in HV networks - Oman MIS case study. 2013 7th IEEE GCC Conference and Exhibition, GCC 2013. 2013. pp. 49-53
@inproceedings{fa331fc28abf425485badf676867ab63,
title = "Measurements and evaluation of harmonics in HV networks - Oman MIS case study",
abstract = "This paper presents a case study about the impacts of industrial loads on power quality. A review of harmonics causes, negative impacts, mitigation techniques, quantification indices and limits are presented. Moreover, harmonics measurements at three grid station that supply the three main industrial areas located in the Main Interconnected System (MIS) of Oman are conducted. Measurement results are compared with limits specified by national and international standards.",
keywords = "Harmonics, Measurements, Power Quality, Standards",
author = "Albadi, {M. H.} and {Al Hinai}, {A. S.} and Al-Badi, {A. H.} and {Al Riyami}, {M. S.} and {Al Hinai}, {S. M.} and {Al Abri}, {R. S.}",
year = "2013",
doi = "10.1109/IEEEGCC.2013.6705747",
language = "English",
isbn = "9781479907243",
pages = "49--53",
booktitle = "2013 7th IEEE GCC Conference and Exhibition, GCC 2013",

}

TY - GEN

T1 - Measurements and evaluation of harmonics in HV networks - Oman MIS case study

AU - Albadi, M. H.

AU - Al Hinai, A. S.

AU - Al-Badi, A. H.

AU - Al Riyami, M. S.

AU - Al Hinai, S. M.

AU - Al Abri, R. S.

PY - 2013

Y1 - 2013

N2 - This paper presents a case study about the impacts of industrial loads on power quality. A review of harmonics causes, negative impacts, mitigation techniques, quantification indices and limits are presented. Moreover, harmonics measurements at three grid station that supply the three main industrial areas located in the Main Interconnected System (MIS) of Oman are conducted. Measurement results are compared with limits specified by national and international standards.

AB - This paper presents a case study about the impacts of industrial loads on power quality. A review of harmonics causes, negative impacts, mitigation techniques, quantification indices and limits are presented. Moreover, harmonics measurements at three grid station that supply the three main industrial areas located in the Main Interconnected System (MIS) of Oman are conducted. Measurement results are compared with limits specified by national and international standards.

KW - Harmonics

KW - Measurements

KW - Power Quality

KW - Standards

UR - http://www.scopus.com/inward/record.url?scp=84893627261&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893627261&partnerID=8YFLogxK

U2 - 10.1109/IEEEGCC.2013.6705747

DO - 10.1109/IEEEGCC.2013.6705747

M3 - Conference contribution

AN - SCOPUS:84893627261

SN - 9781479907243

SP - 49

EP - 53

BT - 2013 7th IEEE GCC Conference and Exhibition, GCC 2013

ER -