High voltage calibration method for the CMS RPC detector

CMS muon group

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.

Original languageEnglish
Article numberC09046
JournalJournal of Instrumentation
Volume14
Issue number9
DOIs
Publication statusPublished - Sept 30 2019