Flow electrification phenomenon in forced air-cooled rotating electric machines

I. A. Metwally, A. A. A-Rahim

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The factors affecting air-flow electrification under both HVDC and HVAC of variable frequency have been investigated experimentally on air flow between coaxial-cylinder and point-to-cylinder systems in a synthetic open cycle. Instantaneous measurements of the air flow electrification (AFE) 'streaming current' and corona current 'radial current' are presented as a function of mass flow rate, air temperature, pressure and relative humidity, electrode configurations, and voltage amplitude, polarity and frequency. The results reveal that both streaming and radial currents augment with voltage, relative humidity, mass flow rate, and temperature. On the other hand, both the streaming and the radial currents do not vary with pressure. Increasing the frequency of the applied HVAC significantly reduces the streaming current, while the radial current increases linearly. Similar trends of the results are observed for both electrode systems. For the point-to-cylinder system under negative HVDC, increasing the mass flow rate drastically reduces both corona inception and breakdown voltages, while positive HVDC gives only a slight effect. The present work confirms the significant role of the AFE on the field failures occurring inside forced air-cooled rotating electric machines. Therefore, such phenomena should be taken into consideration in the design of such machines.

Original languageEnglish
Pages (from-to)966-971
Number of pages6
JournalIEEE Transactions on Dielectrics and Electrical Insulation
Volume5
Issue number6
DOIs
Publication statusPublished - 1998

Fingerprint

Electric machinery
Air
Flow rate
Atmospheric humidity
Electrodes
Electric potential
Electric breakdown
Temperature

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Flow electrification phenomenon in forced air-cooled rotating electric machines. / Metwally, I. A.; A-Rahim, A. A.

In: IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 6, 1998, p. 966-971.

Research output: Contribution to journalArticle

@article{28dee44cabcd49f6b8ca2638f198878a,
title = "Flow electrification phenomenon in forced air-cooled rotating electric machines",
abstract = "The factors affecting air-flow electrification under both HVDC and HVAC of variable frequency have been investigated experimentally on air flow between coaxial-cylinder and point-to-cylinder systems in a synthetic open cycle. Instantaneous measurements of the air flow electrification (AFE) 'streaming current' and corona current 'radial current' are presented as a function of mass flow rate, air temperature, pressure and relative humidity, electrode configurations, and voltage amplitude, polarity and frequency. The results reveal that both streaming and radial currents augment with voltage, relative humidity, mass flow rate, and temperature. On the other hand, both the streaming and the radial currents do not vary with pressure. Increasing the frequency of the applied HVAC significantly reduces the streaming current, while the radial current increases linearly. Similar trends of the results are observed for both electrode systems. For the point-to-cylinder system under negative HVDC, increasing the mass flow rate drastically reduces both corona inception and breakdown voltages, while positive HVDC gives only a slight effect. The present work confirms the significant role of the AFE on the field failures occurring inside forced air-cooled rotating electric machines. Therefore, such phenomena should be taken into consideration in the design of such machines.",
author = "Metwally, {I. A.} and A-Rahim, {A. A.}",
year = "1998",
doi = "10.1109/94.740784",
language = "English",
volume = "5",
pages = "966--971",
journal = "IEEE Transactions on Dielectrics and Electrical Insulation",
issn = "1070-9878",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "6",

}

TY - JOUR

T1 - Flow electrification phenomenon in forced air-cooled rotating electric machines

AU - Metwally, I. A.

AU - A-Rahim, A. A.

PY - 1998

Y1 - 1998

N2 - The factors affecting air-flow electrification under both HVDC and HVAC of variable frequency have been investigated experimentally on air flow between coaxial-cylinder and point-to-cylinder systems in a synthetic open cycle. Instantaneous measurements of the air flow electrification (AFE) 'streaming current' and corona current 'radial current' are presented as a function of mass flow rate, air temperature, pressure and relative humidity, electrode configurations, and voltage amplitude, polarity and frequency. The results reveal that both streaming and radial currents augment with voltage, relative humidity, mass flow rate, and temperature. On the other hand, both the streaming and the radial currents do not vary with pressure. Increasing the frequency of the applied HVAC significantly reduces the streaming current, while the radial current increases linearly. Similar trends of the results are observed for both electrode systems. For the point-to-cylinder system under negative HVDC, increasing the mass flow rate drastically reduces both corona inception and breakdown voltages, while positive HVDC gives only a slight effect. The present work confirms the significant role of the AFE on the field failures occurring inside forced air-cooled rotating electric machines. Therefore, such phenomena should be taken into consideration in the design of such machines.

AB - The factors affecting air-flow electrification under both HVDC and HVAC of variable frequency have been investigated experimentally on air flow between coaxial-cylinder and point-to-cylinder systems in a synthetic open cycle. Instantaneous measurements of the air flow electrification (AFE) 'streaming current' and corona current 'radial current' are presented as a function of mass flow rate, air temperature, pressure and relative humidity, electrode configurations, and voltage amplitude, polarity and frequency. The results reveal that both streaming and radial currents augment with voltage, relative humidity, mass flow rate, and temperature. On the other hand, both the streaming and the radial currents do not vary with pressure. Increasing the frequency of the applied HVAC significantly reduces the streaming current, while the radial current increases linearly. Similar trends of the results are observed for both electrode systems. For the point-to-cylinder system under negative HVDC, increasing the mass flow rate drastically reduces both corona inception and breakdown voltages, while positive HVDC gives only a slight effect. The present work confirms the significant role of the AFE on the field failures occurring inside forced air-cooled rotating electric machines. Therefore, such phenomena should be taken into consideration in the design of such machines.

UR - http://www.scopus.com/inward/record.url?scp=0032309477&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032309477&partnerID=8YFLogxK

U2 - 10.1109/94.740784

DO - 10.1109/94.740784

M3 - Article

VL - 5

SP - 966

EP - 971

JO - IEEE Transactions on Dielectrics and Electrical Insulation

JF - IEEE Transactions on Dielectrics and Electrical Insulation

SN - 1070-9878

IS - 6

ER -