Fast analysis of flavonoids in apple juice on new generation halo column by SPE-HPLC

Imran Ali, Salma M Z Al-Kindy, Fakhreldin O. Suliman, Syed Dilshad Alam

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

A fast SPE-HPLC method is described for the analysis of flavonoids in apple juice. The mobile phase used was water-acetonitrile (60:40, v/v) at 0.80 mL min-1 flow rate with UV detection at 252 nm. The column used was new generation Halo C18 (100 × 46 mm; shell particles; 2.7 μm). The capacity factors were in the range of 0.67 to 20.56, respectively. The separation and resolution factors ranged from 1.18-2.21 and 1.00-10.00, respectively. The values for LOD and LOQ for flavonoids ranged from 0.40-5.5 ng and 2.25-26.0 ng, respectively. The linearity was observed in the concentration ranges of 0.01 to 0.10 mg mL-1 for all flavonoids. The concentrations of quercetin, apigenin, kaemferol and chrysin in apple juice were 4.00, 0.50, 0.40 and 0.25 mg kg-1, respectively. Therefore, the reported method can be used for the quality control of apple juice in food industries. Besides, this method can also be used for the analyses of flavonoids in other fruits and vegetables.

Original languageEnglish
Pages (from-to)2836-2841
Number of pages6
JournalAnalytical Methods
Volume3
Issue number12
DOIs
Publication statusPublished - Dec 2011

Fingerprint

Flavonoids
Apigenin
Quercetin
Vegetables
Fruits
Acetonitrile
Quality control
Flow rate
Water
Industry

ASJC Scopus subject areas

  • Analytical Chemistry
  • Engineering(all)
  • Chemical Engineering(all)

Cite this

Fast analysis of flavonoids in apple juice on new generation halo column by SPE-HPLC. / Ali, Imran; Al-Kindy, Salma M Z; Suliman, Fakhreldin O.; Alam, Syed Dilshad.

In: Analytical Methods, Vol. 3, No. 12, 12.2011, p. 2836-2841.

Research output: Contribution to journalArticle

@article{a7de17af93354de9b5635bb9b4835976,
title = "Fast analysis of flavonoids in apple juice on new generation halo column by SPE-HPLC",
abstract = "A fast SPE-HPLC method is described for the analysis of flavonoids in apple juice. The mobile phase used was water-acetonitrile (60:40, v/v) at 0.80 mL min-1 flow rate with UV detection at 252 nm. The column used was new generation Halo C18 (100 × 46 mm; shell particles; 2.7 μm). The capacity factors were in the range of 0.67 to 20.56, respectively. The separation and resolution factors ranged from 1.18-2.21 and 1.00-10.00, respectively. The values for LOD and LOQ for flavonoids ranged from 0.40-5.5 ng and 2.25-26.0 ng, respectively. The linearity was observed in the concentration ranges of 0.01 to 0.10 mg mL-1 for all flavonoids. The concentrations of quercetin, apigenin, kaemferol and chrysin in apple juice were 4.00, 0.50, 0.40 and 0.25 mg kg-1, respectively. Therefore, the reported method can be used for the quality control of apple juice in food industries. Besides, this method can also be used for the analyses of flavonoids in other fruits and vegetables.",
author = "Imran Ali and Al-Kindy, {Salma M Z} and Suliman, {Fakhreldin O.} and Alam, {Syed Dilshad}",
year = "2011",
month = "12",
doi = "10.1039/c1ay05496a",
language = "English",
volume = "3",
pages = "2836--2841",
journal = "Analytical Methods",
issn = "1759-9660",
publisher = "Royal Society of Chemistry",
number = "12",

}

TY - JOUR

T1 - Fast analysis of flavonoids in apple juice on new generation halo column by SPE-HPLC

AU - Ali, Imran

AU - Al-Kindy, Salma M Z

AU - Suliman, Fakhreldin O.

AU - Alam, Syed Dilshad

PY - 2011/12

Y1 - 2011/12

N2 - A fast SPE-HPLC method is described for the analysis of flavonoids in apple juice. The mobile phase used was water-acetonitrile (60:40, v/v) at 0.80 mL min-1 flow rate with UV detection at 252 nm. The column used was new generation Halo C18 (100 × 46 mm; shell particles; 2.7 μm). The capacity factors were in the range of 0.67 to 20.56, respectively. The separation and resolution factors ranged from 1.18-2.21 and 1.00-10.00, respectively. The values for LOD and LOQ for flavonoids ranged from 0.40-5.5 ng and 2.25-26.0 ng, respectively. The linearity was observed in the concentration ranges of 0.01 to 0.10 mg mL-1 for all flavonoids. The concentrations of quercetin, apigenin, kaemferol and chrysin in apple juice were 4.00, 0.50, 0.40 and 0.25 mg kg-1, respectively. Therefore, the reported method can be used for the quality control of apple juice in food industries. Besides, this method can also be used for the analyses of flavonoids in other fruits and vegetables.

AB - A fast SPE-HPLC method is described for the analysis of flavonoids in apple juice. The mobile phase used was water-acetonitrile (60:40, v/v) at 0.80 mL min-1 flow rate with UV detection at 252 nm. The column used was new generation Halo C18 (100 × 46 mm; shell particles; 2.7 μm). The capacity factors were in the range of 0.67 to 20.56, respectively. The separation and resolution factors ranged from 1.18-2.21 and 1.00-10.00, respectively. The values for LOD and LOQ for flavonoids ranged from 0.40-5.5 ng and 2.25-26.0 ng, respectively. The linearity was observed in the concentration ranges of 0.01 to 0.10 mg mL-1 for all flavonoids. The concentrations of quercetin, apigenin, kaemferol and chrysin in apple juice were 4.00, 0.50, 0.40 and 0.25 mg kg-1, respectively. Therefore, the reported method can be used for the quality control of apple juice in food industries. Besides, this method can also be used for the analyses of flavonoids in other fruits and vegetables.

UR - http://www.scopus.com/inward/record.url?scp=82555169321&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82555169321&partnerID=8YFLogxK

U2 - 10.1039/c1ay05496a

DO - 10.1039/c1ay05496a

M3 - Article

VL - 3

SP - 2836

EP - 2841

JO - Analytical Methods

JF - Analytical Methods

SN - 1759-9660

IS - 12

ER -