Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I)

A. S. Ayan, N. Akchurin, U. Akgun, E. W. Anderson, Z. Bagoly, G. Y. Bencze, P. Bruecken, G. Debreczeni, I. Dumanoglu, E. Eskut, A. Fenyvesi, V. Gavrilov, A. Gribushin, C. Hajdu, J. Hauptman, A. Kayis, V. Kolosov, S. Kuleshov, J. P. Merlo, M. MillerE. McCliment, J. Molnar, A. Nikitin, Y. Onel, G. Onengut, D. Osborne, N. Ozdes-Koca, V. Pikalov, A. Polatoz, I. Schmidt, M. Serin, R. Sever, V. Stolin, A. Ulyanov, A. Umashev, S. Uzunian, G. Vesztergombi, D. Winn, A. Yershov, P. Zalan, M. Zeyrek

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

The first pre-production-prototype (PPP-I) of the quartz fibre calorimeter of the CMS detector has been tested at CERN. The calorimeter consists of quartz fibres embedded in an iron matrix. Results are presented on the energy resolution and on the signal uniformity of the prototype for electrons and pions and the signal uniformity and linearity.

Original languageEnglish
JournalJournal of Physics G: Nuclear and Particle Physics
Volume30
Issue number12
DOIs
Publication statusPublished - Dec 2004

Fingerprint

linearity
calorimeters
quartz
prototypes
fibers
pions
iron
energy
detectors
matrices
electrons

ASJC Scopus subject areas

  • Physics and Astronomy(all)
  • Nuclear and High Energy Physics

Cite this

Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I). / Ayan, A. S.; Akchurin, N.; Akgun, U.; Anderson, E. W.; Bagoly, Z.; Bencze, G. Y.; Bruecken, P.; Debreczeni, G.; Dumanoglu, I.; Eskut, E.; Fenyvesi, A.; Gavrilov, V.; Gribushin, A.; Hajdu, C.; Hauptman, J.; Kayis, A.; Kolosov, V.; Kuleshov, S.; Merlo, J. P.; Miller, M.; McCliment, E.; Molnar, J.; Nikitin, A.; Onel, Y.; Onengut, G.; Osborne, D.; Ozdes-Koca, N.; Pikalov, V.; Polatoz, A.; Schmidt, I.; Serin, M.; Sever, R.; Stolin, V.; Ulyanov, A.; Umashev, A.; Uzunian, S.; Vesztergombi, G.; Winn, D.; Yershov, A.; Zalan, P.; Zeyrek, M.

In: Journal of Physics G: Nuclear and Particle Physics, Vol. 30, No. 12, 12.2004.

Research output: Contribution to journalArticle

Ayan, AS, Akchurin, N, Akgun, U, Anderson, EW, Bagoly, Z, Bencze, GY, Bruecken, P, Debreczeni, G, Dumanoglu, I, Eskut, E, Fenyvesi, A, Gavrilov, V, Gribushin, A, Hajdu, C, Hauptman, J, Kayis, A, Kolosov, V, Kuleshov, S, Merlo, JP, Miller, M, McCliment, E, Molnar, J, Nikitin, A, Onel, Y, Onengut, G, Osborne, D, Ozdes-Koca, N, Pikalov, V, Polatoz, A, Schmidt, I, Serin, M, Sever, R, Stolin, V, Ulyanov, A, Umashev, A, Uzunian, S, Vesztergombi, G, Winn, D, Yershov, A, Zalan, P & Zeyrek, M 2004, 'Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I)', Journal of Physics G: Nuclear and Particle Physics, vol. 30, no. 12. https://doi.org/10.1088/0954-3899/30/12/N01
Ayan, A. S. ; Akchurin, N. ; Akgun, U. ; Anderson, E. W. ; Bagoly, Z. ; Bencze, G. Y. ; Bruecken, P. ; Debreczeni, G. ; Dumanoglu, I. ; Eskut, E. ; Fenyvesi, A. ; Gavrilov, V. ; Gribushin, A. ; Hajdu, C. ; Hauptman, J. ; Kayis, A. ; Kolosov, V. ; Kuleshov, S. ; Merlo, J. P. ; Miller, M. ; McCliment, E. ; Molnar, J. ; Nikitin, A. ; Onel, Y. ; Onengut, G. ; Osborne, D. ; Ozdes-Koca, N. ; Pikalov, V. ; Polatoz, A. ; Schmidt, I. ; Serin, M. ; Sever, R. ; Stolin, V. ; Ulyanov, A. ; Umashev, A. ; Uzunian, S. ; Vesztergombi, G. ; Winn, D. ; Yershov, A. ; Zalan, P. ; Zeyrek, M. / Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I). In: Journal of Physics G: Nuclear and Particle Physics. 2004 ; Vol. 30, No. 12.
@article{1280b282776c434591c0dc5de51d5e8c,
title = "Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I)",
abstract = "The first pre-production-prototype (PPP-I) of the quartz fibre calorimeter of the CMS detector has been tested at CERN. The calorimeter consists of quartz fibres embedded in an iron matrix. Results are presented on the energy resolution and on the signal uniformity of the prototype for electrons and pions and the signal uniformity and linearity.",
author = "Ayan, {A. S.} and N. Akchurin and U. Akgun and Anderson, {E. W.} and Z. Bagoly and Bencze, {G. Y.} and P. Bruecken and G. Debreczeni and I. Dumanoglu and E. Eskut and A. Fenyvesi and V. Gavrilov and A. Gribushin and C. Hajdu and J. Hauptman and A. Kayis and V. Kolosov and S. Kuleshov and Merlo, {J. P.} and M. Miller and E. McCliment and J. Molnar and A. Nikitin and Y. Onel and G. Onengut and D. Osborne and N. Ozdes-Koca and V. Pikalov and A. Polatoz and I. Schmidt and M. Serin and R. Sever and V. Stolin and A. Ulyanov and A. Umashev and S. Uzunian and G. Vesztergombi and D. Winn and A. Yershov and P. Zalan and M. Zeyrek",
year = "2004",
month = "12",
doi = "10.1088/0954-3899/30/12/N01",
language = "English",
volume = "30",
journal = "Journal of Physics G: Nuclear and Particle Physics",
issn = "0954-3899",
publisher = "IOP Publishing Ltd.",
number = "12",

}

TY - JOUR

T1 - Energy resolution and the linearity of the CMS forward quartz fibre calorimeter pre-production-prototype (PPP-I)

AU - Ayan, A. S.

AU - Akchurin, N.

AU - Akgun, U.

AU - Anderson, E. W.

AU - Bagoly, Z.

AU - Bencze, G. Y.

AU - Bruecken, P.

AU - Debreczeni, G.

AU - Dumanoglu, I.

AU - Eskut, E.

AU - Fenyvesi, A.

AU - Gavrilov, V.

AU - Gribushin, A.

AU - Hajdu, C.

AU - Hauptman, J.

AU - Kayis, A.

AU - Kolosov, V.

AU - Kuleshov, S.

AU - Merlo, J. P.

AU - Miller, M.

AU - McCliment, E.

AU - Molnar, J.

AU - Nikitin, A.

AU - Onel, Y.

AU - Onengut, G.

AU - Osborne, D.

AU - Ozdes-Koca, N.

AU - Pikalov, V.

AU - Polatoz, A.

AU - Schmidt, I.

AU - Serin, M.

AU - Sever, R.

AU - Stolin, V.

AU - Ulyanov, A.

AU - Umashev, A.

AU - Uzunian, S.

AU - Vesztergombi, G.

AU - Winn, D.

AU - Yershov, A.

AU - Zalan, P.

AU - Zeyrek, M.

PY - 2004/12

Y1 - 2004/12

N2 - The first pre-production-prototype (PPP-I) of the quartz fibre calorimeter of the CMS detector has been tested at CERN. The calorimeter consists of quartz fibres embedded in an iron matrix. Results are presented on the energy resolution and on the signal uniformity of the prototype for electrons and pions and the signal uniformity and linearity.

AB - The first pre-production-prototype (PPP-I) of the quartz fibre calorimeter of the CMS detector has been tested at CERN. The calorimeter consists of quartz fibres embedded in an iron matrix. Results are presented on the energy resolution and on the signal uniformity of the prototype for electrons and pions and the signal uniformity and linearity.

UR - http://www.scopus.com/inward/record.url?scp=10944260589&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=10944260589&partnerID=8YFLogxK

U2 - 10.1088/0954-3899/30/12/N01

DO - 10.1088/0954-3899/30/12/N01

M3 - Article

AN - SCOPUS:10944260589

VL - 30

JO - Journal of Physics G: Nuclear and Particle Physics

JF - Journal of Physics G: Nuclear and Particle Physics

SN - 0954-3899

IS - 12

ER -