Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran

Mahmoud Mohammadyan, Mahboobeh Ghoochani, Itai Kloog, Sabah Ahmed Abdul-Wahab, Kaan Yetilmezsoy, Behzad Heibati, Krystal J. Godri Pollitt

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.

Original languageEnglish
Article number235
JournalEnvironmental Monitoring and Assessment
Volume189
Issue number5
DOIs
Publication statusPublished - May 1 2017

Fingerprint

Air pollution
atmospheric pollution
indoor air
Developing countries
Air quality
particulate matter
air quality
developing world
Health
office
corridor
effect
health
medical science

Keywords

  • Indoor air quality
  • Iran
  • PM
  • PM
  • PM

ASJC Scopus subject areas

  • Environmental Science(all)
  • Pollution
  • Management, Monitoring, Policy and Law

Cite this

Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran. / Mohammadyan, Mahmoud; Ghoochani, Mahboobeh; Kloog, Itai; Abdul-Wahab, Sabah Ahmed; Yetilmezsoy, Kaan; Heibati, Behzad; Godri Pollitt, Krystal J.

In: Environmental Monitoring and Assessment, Vol. 189, No. 5, 235, 01.05.2017.

Research output: Contribution to journalArticle

Mohammadyan, Mahmoud ; Ghoochani, Mahboobeh ; Kloog, Itai ; Abdul-Wahab, Sabah Ahmed ; Yetilmezsoy, Kaan ; Heibati, Behzad ; Godri Pollitt, Krystal J. / Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran. In: Environmental Monitoring and Assessment. 2017 ; Vol. 189, No. 5.
@article{e2c7f5e789074e1780c72ee6d671079b,
title = "Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran",
abstract = "The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.",
keywords = "Indoor air quality, Iran, PM, PM, PM",
author = "Mahmoud Mohammadyan and Mahboobeh Ghoochani and Itai Kloog and Abdul-Wahab, {Sabah Ahmed} and Kaan Yetilmezsoy and Behzad Heibati and {Godri Pollitt}, {Krystal J.}",
year = "2017",
month = "5",
day = "1",
doi = "10.1007/s10661-017-5951-1",
language = "English",
volume = "189",
journal = "Environmental Monitoring and Assessment",
issn = "0167-6369",
publisher = "Springer Netherlands",
number = "5",

}

TY - JOUR

T1 - Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran

AU - Mohammadyan, Mahmoud

AU - Ghoochani, Mahboobeh

AU - Kloog, Itai

AU - Abdul-Wahab, Sabah Ahmed

AU - Yetilmezsoy, Kaan

AU - Heibati, Behzad

AU - Godri Pollitt, Krystal J.

PY - 2017/5/1

Y1 - 2017/5/1

N2 - The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.

AB - The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 μm (PM1.0), 2.5 μm (PM2.5), and 10 μm (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 ± 32.1 μg/m3) and outdoor PM10 concentrations (46.5 ± 26.0 μg/m3), indoor PM2.5 (22.6 ± 17.4 μg/m3) and outdoor PM2.5 concentration (22.2 ± 15.4 μg/m3), or indoor PM1.0 (14.5 ± 13.4 μg/m3) and outdoor mean PM1.0 concentrations (14.2 ± 12.3 μg/m3). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.

KW - Indoor air quality

KW - Iran

KW - PM

KW - PM

KW - PM

UR - http://www.scopus.com/inward/record.url?scp=85018904796&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85018904796&partnerID=8YFLogxK

U2 - 10.1007/s10661-017-5951-1

DO - 10.1007/s10661-017-5951-1

M3 - Article

C2 - 28451957

AN - SCOPUS:85018904796

VL - 189

JO - Environmental Monitoring and Assessment

JF - Environmental Monitoring and Assessment

SN - 0167-6369

IS - 5

M1 - 235

ER -