Analysis of different factors affecting cathodic protection for deep well casings

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

This paper introduces a comparative theoretical investigation of the conventional cathodic protection (CP) and the pulse cathodic protection (PCP) systems to show how both of them behave under different operating conditions. The effectiveness of the PCP system is also highlighted for a typical large-scale configuration as well as some field measurements have been carried out. The performance of PCP system has been analyzed in the light of getting better protection-current distribution along the protected well casing at reduced anode current together with reducing the stray current (corrosion) at any nearby unprotected structure(s). Many factors have been investigated to show their effects on the performance of the CP system, namely, soil resistivity, voltage pulse waveform and frequency, and multi-layer soil. In addition, the performance of both the conventional CP and the PCP systems has been compared to that when utilizing unused/abandoned well casing as anode energized by the conventional CP system. The PCP system shows better performance than that of the conventional CP, and a similar performance at high soil resistivity to that when using unused/abandoned well casing. On the other hand, the utilization of the unused/abandoned well casing gives superior performance, especially at low soil resistivities, where the protection-current profiles of both the conventional CP and the PCP systems decay sharply.

Original languageEnglish
Pages (from-to)245-251
Number of pages7
JournalMaterials and Corrosion
Volume61
Issue number3
DOIs
Publication statusPublished - Mar 2010

Fingerprint

Cathodic protection
well
Abandoned wells
electrical resistivity
Soils
soil
analysis
protection system
Anodes
corrosion
Corrosion

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Environmental Chemistry
  • Materials Chemistry
  • Metals and Alloys
  • Surfaces, Coatings and Films

Cite this

Analysis of different factors affecting cathodic protection for deep well casings. / Metwally, I. A.; Al-Badi, A. H.

In: Materials and Corrosion, Vol. 61, No. 3, 03.2010, p. 245-251.

Research output: Contribution to journalArticle

@article{cc8c834098574bceb328aae702df5b35,
title = "Analysis of different factors affecting cathodic protection for deep well casings",
abstract = "This paper introduces a comparative theoretical investigation of the conventional cathodic protection (CP) and the pulse cathodic protection (PCP) systems to show how both of them behave under different operating conditions. The effectiveness of the PCP system is also highlighted for a typical large-scale configuration as well as some field measurements have been carried out. The performance of PCP system has been analyzed in the light of getting better protection-current distribution along the protected well casing at reduced anode current together with reducing the stray current (corrosion) at any nearby unprotected structure(s). Many factors have been investigated to show their effects on the performance of the CP system, namely, soil resistivity, voltage pulse waveform and frequency, and multi-layer soil. In addition, the performance of both the conventional CP and the PCP systems has been compared to that when utilizing unused/abandoned well casing as anode energized by the conventional CP system. The PCP system shows better performance than that of the conventional CP, and a similar performance at high soil resistivity to that when using unused/abandoned well casing. On the other hand, the utilization of the unused/abandoned well casing gives superior performance, especially at low soil resistivities, where the protection-current profiles of both the conventional CP and the PCP systems decay sharply.",
author = "Metwally, {I. A.} and Al-Badi, {A. H.}",
year = "2010",
month = "3",
doi = "10.1002/maco.200905272",
language = "English",
volume = "61",
pages = "245--251",
journal = "Materials and Corrosion - Werkstoffe und Korrosion",
issn = "0043-2822",
publisher = "John Wiley and Sons Ltd",
number = "3",

}

TY - JOUR

T1 - Analysis of different factors affecting cathodic protection for deep well casings

AU - Metwally, I. A.

AU - Al-Badi, A. H.

PY - 2010/3

Y1 - 2010/3

N2 - This paper introduces a comparative theoretical investigation of the conventional cathodic protection (CP) and the pulse cathodic protection (PCP) systems to show how both of them behave under different operating conditions. The effectiveness of the PCP system is also highlighted for a typical large-scale configuration as well as some field measurements have been carried out. The performance of PCP system has been analyzed in the light of getting better protection-current distribution along the protected well casing at reduced anode current together with reducing the stray current (corrosion) at any nearby unprotected structure(s). Many factors have been investigated to show their effects on the performance of the CP system, namely, soil resistivity, voltage pulse waveform and frequency, and multi-layer soil. In addition, the performance of both the conventional CP and the PCP systems has been compared to that when utilizing unused/abandoned well casing as anode energized by the conventional CP system. The PCP system shows better performance than that of the conventional CP, and a similar performance at high soil resistivity to that when using unused/abandoned well casing. On the other hand, the utilization of the unused/abandoned well casing gives superior performance, especially at low soil resistivities, where the protection-current profiles of both the conventional CP and the PCP systems decay sharply.

AB - This paper introduces a comparative theoretical investigation of the conventional cathodic protection (CP) and the pulse cathodic protection (PCP) systems to show how both of them behave under different operating conditions. The effectiveness of the PCP system is also highlighted for a typical large-scale configuration as well as some field measurements have been carried out. The performance of PCP system has been analyzed in the light of getting better protection-current distribution along the protected well casing at reduced anode current together with reducing the stray current (corrosion) at any nearby unprotected structure(s). Many factors have been investigated to show their effects on the performance of the CP system, namely, soil resistivity, voltage pulse waveform and frequency, and multi-layer soil. In addition, the performance of both the conventional CP and the PCP systems has been compared to that when utilizing unused/abandoned well casing as anode energized by the conventional CP system. The PCP system shows better performance than that of the conventional CP, and a similar performance at high soil resistivity to that when using unused/abandoned well casing. On the other hand, the utilization of the unused/abandoned well casing gives superior performance, especially at low soil resistivities, where the protection-current profiles of both the conventional CP and the PCP systems decay sharply.

UR - http://www.scopus.com/inward/record.url?scp=77949667474&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77949667474&partnerID=8YFLogxK

U2 - 10.1002/maco.200905272

DO - 10.1002/maco.200905272

M3 - Article

AN - SCOPUS:77949667474

VL - 61

SP - 245

EP - 251

JO - Materials and Corrosion - Werkstoffe und Korrosion

JF - Materials and Corrosion - Werkstoffe und Korrosion

SN - 0043-2822

IS - 3

ER -