An adaptive foot device for increased gait and postural stability in lower limb orthoses and exoskeletons

Jungwon Yoon, R. Prasanth Kumar, Abdullah Özer

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Assistive devices and exoskeletons have critical importance for people with manipulative and locomotive disabilities. One of the major purposes of such devices when used for lower extremities is to help provide the postural or gait stability of the user. However, current lower extremity exoskeletons available lack the sufficient foot support area to guarantee a safe operation for the rehabilitation of patients, and normal posture/gait for users carrying heavy loads on backpack. As a result, these devices may require an intensive control effort to supply the posture or gait stability and can demand additional therapist help during rehabilitation. In this paper, we proposed a novel adaptive foot system to enhance the required stability of lower extremity exoskeletons as an add-on device. The method essentially aims to automatically extend the support area behind the heel during walking. The proposed adaptive foot system can extend passively during stance and retract during the toe rocker phase, which allows increased support areas during stance and prevent collisions to the level ground during swing. It is practical to implement and can be employed without necessitating an actuation power. The proposed wearable system will particularly be valuable in rehabilitation for enhancing the stability where safety of patients is particularly critical. It is also anticipated that the system can be a complementary device for current exoskeletons or humanoid robots to enhance their stability. A detailed description and numerical analysis of the stability in sagittal plane is presented for postural and gait cases in this paper. Experiments have been also conducted to prove the effectiveness of the adaptive wearable device for postural and gait stability.

Original languageEnglish
Pages (from-to)515-524
Number of pages10
JournalInternational Journal of Control, Automation and Systems
Volume9
Issue number3
DOIs
Publication statusPublished - Jun 2011

Fingerprint

Patient rehabilitation
Convergence of numerical methods
Locomotives
Numerical analysis
Robots
Experiments
Exoskeleton (Robotics)

Keywords

  • Adaptive foot device
  • Backpack
  • Lower extremity exoskeleton
  • Rehabilitation
  • Stability

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Computer Science Applications

Cite this

An adaptive foot device for increased gait and postural stability in lower limb orthoses and exoskeletons. / Yoon, Jungwon; Kumar, R. Prasanth; Özer, Abdullah.

In: International Journal of Control, Automation and Systems, Vol. 9, No. 3, 06.2011, p. 515-524.

Research output: Contribution to journalArticle

@article{0bc294bc330d4b6cb5e6d157d46cdae1,
title = "An adaptive foot device for increased gait and postural stability in lower limb orthoses and exoskeletons",
abstract = "Assistive devices and exoskeletons have critical importance for people with manipulative and locomotive disabilities. One of the major purposes of such devices when used for lower extremities is to help provide the postural or gait stability of the user. However, current lower extremity exoskeletons available lack the sufficient foot support area to guarantee a safe operation for the rehabilitation of patients, and normal posture/gait for users carrying heavy loads on backpack. As a result, these devices may require an intensive control effort to supply the posture or gait stability and can demand additional therapist help during rehabilitation. In this paper, we proposed a novel adaptive foot system to enhance the required stability of lower extremity exoskeletons as an add-on device. The method essentially aims to automatically extend the support area behind the heel during walking. The proposed adaptive foot system can extend passively during stance and retract during the toe rocker phase, which allows increased support areas during stance and prevent collisions to the level ground during swing. It is practical to implement and can be employed without necessitating an actuation power. The proposed wearable system will particularly be valuable in rehabilitation for enhancing the stability where safety of patients is particularly critical. It is also anticipated that the system can be a complementary device for current exoskeletons or humanoid robots to enhance their stability. A detailed description and numerical analysis of the stability in sagittal plane is presented for postural and gait cases in this paper. Experiments have been also conducted to prove the effectiveness of the adaptive wearable device for postural and gait stability.",
keywords = "Adaptive foot device, Backpack, Lower extremity exoskeleton, Rehabilitation, Stability",
author = "Jungwon Yoon and Kumar, {R. Prasanth} and Abdullah {\"O}zer",
year = "2011",
month = "6",
doi = "10.1007/s12555-011-0311-3",
language = "English",
volume = "9",
pages = "515--524",
journal = "International Journal of Control, Automation and Systems",
issn = "1598-6446",
publisher = "Institute of Control, Robotics and Systems",
number = "3",

}

TY - JOUR

T1 - An adaptive foot device for increased gait and postural stability in lower limb orthoses and exoskeletons

AU - Yoon, Jungwon

AU - Kumar, R. Prasanth

AU - Özer, Abdullah

PY - 2011/6

Y1 - 2011/6

N2 - Assistive devices and exoskeletons have critical importance for people with manipulative and locomotive disabilities. One of the major purposes of such devices when used for lower extremities is to help provide the postural or gait stability of the user. However, current lower extremity exoskeletons available lack the sufficient foot support area to guarantee a safe operation for the rehabilitation of patients, and normal posture/gait for users carrying heavy loads on backpack. As a result, these devices may require an intensive control effort to supply the posture or gait stability and can demand additional therapist help during rehabilitation. In this paper, we proposed a novel adaptive foot system to enhance the required stability of lower extremity exoskeletons as an add-on device. The method essentially aims to automatically extend the support area behind the heel during walking. The proposed adaptive foot system can extend passively during stance and retract during the toe rocker phase, which allows increased support areas during stance and prevent collisions to the level ground during swing. It is practical to implement and can be employed without necessitating an actuation power. The proposed wearable system will particularly be valuable in rehabilitation for enhancing the stability where safety of patients is particularly critical. It is also anticipated that the system can be a complementary device for current exoskeletons or humanoid robots to enhance their stability. A detailed description and numerical analysis of the stability in sagittal plane is presented for postural and gait cases in this paper. Experiments have been also conducted to prove the effectiveness of the adaptive wearable device for postural and gait stability.

AB - Assistive devices and exoskeletons have critical importance for people with manipulative and locomotive disabilities. One of the major purposes of such devices when used for lower extremities is to help provide the postural or gait stability of the user. However, current lower extremity exoskeletons available lack the sufficient foot support area to guarantee a safe operation for the rehabilitation of patients, and normal posture/gait for users carrying heavy loads on backpack. As a result, these devices may require an intensive control effort to supply the posture or gait stability and can demand additional therapist help during rehabilitation. In this paper, we proposed a novel adaptive foot system to enhance the required stability of lower extremity exoskeletons as an add-on device. The method essentially aims to automatically extend the support area behind the heel during walking. The proposed adaptive foot system can extend passively during stance and retract during the toe rocker phase, which allows increased support areas during stance and prevent collisions to the level ground during swing. It is practical to implement and can be employed without necessitating an actuation power. The proposed wearable system will particularly be valuable in rehabilitation for enhancing the stability where safety of patients is particularly critical. It is also anticipated that the system can be a complementary device for current exoskeletons or humanoid robots to enhance their stability. A detailed description and numerical analysis of the stability in sagittal plane is presented for postural and gait cases in this paper. Experiments have been also conducted to prove the effectiveness of the adaptive wearable device for postural and gait stability.

KW - Adaptive foot device

KW - Backpack

KW - Lower extremity exoskeleton

KW - Rehabilitation

KW - Stability

UR - http://www.scopus.com/inward/record.url?scp=80052667077&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052667077&partnerID=8YFLogxK

U2 - 10.1007/s12555-011-0311-3

DO - 10.1007/s12555-011-0311-3

M3 - Article

AN - SCOPUS:80052667077

VL - 9

SP - 515

EP - 524

JO - International Journal of Control, Automation and Systems

JF - International Journal of Control, Automation and Systems

SN - 1598-6446

IS - 3

ER -