Technetium-99m sestamibi uptake in a maxilla brown tumor

Isis W. Gayed*, Shehab M. Elshazly, Russell S. Vang, Bruce J. Barron, Lamk M. Lamki

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

11 اقتباسات (Scopus)

ملخص

Brown tumors have been reported to take up TI-201 when dual-tracer parathyroid scintigraphy using TI-201 and Tc-99m pertechnetate was performed. With the change to the more favorable Tc-99m sestamibi para-thyroid scanning, similar phenomena of tracer uptake in brown tumors have been reported. The authors describe a 44-year-old man with a left maxillary swelling. Laboratory investigations revealed elevated parathyroid hormone levels. Computed tomography of the head showed a left maxillary expansile mass. Subsequently, a Tc-99m sestamibi scan was performed to rule out a parathyroid adenoma. Left inferior parathyroid retention of the tracer was seen, indicating a parathyroid adenoma. An incidental finding was the uptake of Tc-99m MIBI in the left maxillary brown tumor. This case suggests the utility and possible specificity of Tc-99m MIBI uptake in diagnosing brown tumors.

اللغة الأصليةEnglish
الصفحات (من إلى)65-67
عدد الصفحات3
دوريةClinical Nuclear Medicine
مستوى الصوت26
رقم الإصدار1
المعرِّفات الرقمية للأشياء
حالة النشرPublished - 2001
منشور خارجيًانعم

ASJC Scopus subject areas

  • ???subjectarea.asjc.2700.2741???

بصمة

أدرس بدقة موضوعات البحث “Technetium-99m sestamibi uptake in a maxilla brown tumor'. فهما يشكلان معًا بصمة فريدة.