Novel designs of wideband Rogowski coils for high pulsed current measurement

Ibrahim A. Metwally*

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

25 اقتباسات (Scopus)

ملخص

This study presents design, calibration and testing of six novel flat-spiral self-integrating Rogowski coils wound in two layers. These coils are two varnished-wire wound coils with air and ferrite cores (RC1 and RC2, respectively), two flat-twin wire wound coils with air and ferrite cores (RC3 and RC4, respectively) and two coaxial-cable wound coils with and without the insulating jacket and with ferrite core and RC5 and RC6, respectively. All coil parameters are calculated and good agreement is found between these values and the corresponding measured ones. Coil sensitivity decreases as coil-to-wire separation increases and so does mutual inductance between the coil and the current-carrying wire. Linearity of all coil sensitivities are checked for different separations and waveforms, and good agreement is found. Designed coils with ferrite core give better response than those with air core because the low cutoff frequency decreases. On the contrary, the droop effect is slightly observed for coils wound on wooden core, where RC4 and RC6 give the best response. Finally, the frequency response analysis for all coils shows that the percentage relative errors of the measured and the calculated coil sensitivities are within ±0.1%.

اللغة الأصليةEnglish
الصفحات (من إلى)9-16
عدد الصفحات8
دوريةIET Science, Measurement and Technology
مستوى الصوت8
رقم الإصدار1
المعرِّفات الرقمية للأشياء
حالة النشرPublished - 2014

ASJC Scopus subject areas

  • ???subjectarea.asjc.3100.3107???
  • ???subjectarea.asjc.2200.2208???

بصمة

أدرس بدقة موضوعات البحث “Novel designs of wideband Rogowski coils for high pulsed current measurement'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا