TY - GEN
T1 - New three-level voltage source inverter with different 25 space voltage vectors
AU - Saied, M. H.
AU - Mostafa, M. Z.
AU - Abdel- Moneim, T. M.
AU - Yousef, H. A.
PY - 2007
Y1 - 2007
N2 - This paper presents a new switching strategy controling a new three-level voltage source inverter, resulting in different 25 space voltage-vectors. The new inverter combines some desirable features of two and three-level inverters. The proposed open-leg switching strategy intentionally opens one of the three inverter-legs per-time, in a pre-planned sequence. Thus, the number of allowed states becomes 64 compared to 27 originally proposed by other modulation strategies. For a wye-connected load operating at low modulation index (M<0.5 p.u.), the output phase-voltage becomes a seven-level, 12-step waveform, instead of the 6-step one. Thus, the total harmonic distortion is highly reduced. Three new conduction-modes are presented, each verifies a reduced common-mode-voltage time-variation (dv/dt), low third harmonic content, and reduced switching frequency harmonics. For higher modulation indexes, a 4 th conduction mode is presented, eliminating the low frequency harmonics in the neutral-point current, consequently reducing the dc-link capacitors sizes, and cost. Analytical models, computer simulation results, and experimental verification are presented.
AB - This paper presents a new switching strategy controling a new three-level voltage source inverter, resulting in different 25 space voltage-vectors. The new inverter combines some desirable features of two and three-level inverters. The proposed open-leg switching strategy intentionally opens one of the three inverter-legs per-time, in a pre-planned sequence. Thus, the number of allowed states becomes 64 compared to 27 originally proposed by other modulation strategies. For a wye-connected load operating at low modulation index (M<0.5 p.u.), the output phase-voltage becomes a seven-level, 12-step waveform, instead of the 6-step one. Thus, the total harmonic distortion is highly reduced. Three new conduction-modes are presented, each verifies a reduced common-mode-voltage time-variation (dv/dt), low third harmonic content, and reduced switching frequency harmonics. For higher modulation indexes, a 4 th conduction mode is presented, eliminating the low frequency harmonics in the neutral-point current, consequently reducing the dc-link capacitors sizes, and cost. Analytical models, computer simulation results, and experimental verification are presented.
KW - 150° conduction-mode
KW - Neutral point clamped
KW - Three-level converter
KW - Total harmonic distortion
KW - Voltage source inverters
UR - http://www.scopus.com/inward/record.url?scp=51749096942&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=51749096942&partnerID=8YFLogxK
U2 - 10.1109/ICEE.2007.4287282
DO - 10.1109/ICEE.2007.4287282
M3 - Conference contribution
AN - SCOPUS:51749096942
SN - 142440892X
SN - 9781424408924
T3 - 2007 International Conference on Electrical Engineering, ICEE
BT - 2007 International Conference on Electrical Engineering, ICEE
T2 - 2007 International Conference on Electrical Engineering, ICEE
Y2 - 11 April 2007 through 12 April 2007
ER -