Minimizing the environmental impact of the envisaged expansion in power generation in main interconnected system of Oman

نتاج البحث: Conference contribution

1 اقتباس (Scopus)

ملخص

This paper presents the results of a study carried out to estimate the DSM energy saving potential in commercial, and government/institutional sectors of Oman and evaluates its impact on generation capacity, energy and pollutants savings in the main interconnected system. The end-use (lighting and air-conditioning) energy consumption data have been collected in two major segments of the commercial sector for simplicity. The study has found that due to DSM the capacity saving is about 300 MW, the overall energy saving is about 23.7 TWh and C02 equivalent saving is about 13 million tons for the whole planning horizon. The total avoided cost in generation and capacity saving is about 346 million dollars.

اللغة الأصليةEnglish
عنوان منشور المضيف2008 IEEE International Systems Conference Proceedings, SysCon 2008
الصفحات411-414
عدد الصفحات4
المعرِّفات الرقمية للأشياء
حالة النشرPublished - 2008
الحدث2008 IEEE International Systems Conference Proceedings, SysCon 2008 - Montreal, QC, Canada
المدة: أبريل ٧ ٢٠٠٨أبريل ١٠ ٢٠٠٨

سلسلة المنشورات

الاسم2008 IEEE International Systems Conference Proceedings, SysCon 2008

Other

Other2008 IEEE International Systems Conference Proceedings, SysCon 2008
الدولة/الإقليمCanada
المدينةMontreal, QC
المدة٤/٧/٠٨٤/١٠/٠٨