Experiences from the RPC data taking during the CMS RUN-2

M. A. Shah*, A. Samalan, M. Tytgat, N. Zaganidis, G. A. Alves, F. Marujo, F. Torres Da Silva De Araujo, E. M. Da Costa, D. De Jesus Damiao, H. Nogima, A. Santoro, S. Fonseca De Souza, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Soultanov, M. Bonchev, A. DimitrovL. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, C. Bernal, A. Cabrera, J. Fraga, A. Sarkar, S. Elsayed, Y. Assran, M. El Sawy, M. A. Mahmoud, Y. Mohammed, C. Combaret, M. Gouzevitch, G. Grenier, I. Laktineh, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, V. Bhatnagar, R. Gupta, P. Kumari, J. Singh, V. Amoozegar, B. Boghrati, M. Ebraimi, R. Ghasemi, M. Mohammadi Najafabadi, E. Zareian, M. Abbrescia, R. Aly, W. Elmetenawee, N. De Filippis, A. Gelmi, G. Iaselli, S. Leszki, F. Loddo, I. Margjeka, G. Pugliese, D. Ramos, M. Caponero, L. Benussi, S. Bianco, S. Colafranceschi, A. Russo, L. Passamonti, D. Piccolo, D. Pierluigi, G. Saviano, S. Buontempo, A. Di Crescenzo, F. Fienga, G. De Lellis, L. Lista, S. Meola, P. Paolucci, A. Braghieri, P. Salvini, P. Montagna, C. Riccardi, P. Vitulo, B. Francois, T. J. Kim, J. Park, S. Y. Choi, B. Hong, K. S. Lee, J. Goh, H. Lee, J. Eysermans, C. Uribe Estrada, I. Pedraza, H. Castilla-Valdez, A. Sanchez-Hernandez, C. A.Mondragon Herrera, D. A.Perez Navarro, G. A.Ayala Sanchez, S. Carrillo, E. Vazquez, A. Radi, A. Ahmad, I. Asghar, H. Hoorani, S. Muhammad, B. Mandelli, R. Guida, I. Crotty

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

1 اقتباس (Scopus)

ملخص

The CMS experiment recorded 177.75 fb-1 of proton-proton collision data during the RUN-1 and RUN-2 data taking period. Successful data taking at increasing instantaneous luminosities with the evolving detector configuration was a big achievement of the collaboration. The CMS RPC system provided redundant information for the robust muon triggering, reconstruction, and identification. To ensure stable data taking, the CMS RPC collaboration has performed detector operation, calibration, and performance studies. Various software and related tools are developed and maintained accordingly. In this paper, the overall performance of the CMS RPC system and experiences of the data taking during the RUN-2 period are summarised.

اللغة الأصليةEnglish
رقم المقالC10027
دوريةJournal of Instrumentation
مستوى الصوت15
رقم الإصدار10
المعرِّفات الرقمية للأشياء
حالة النشرPublished - أكتوبر 2020

ASJC Scopus subject areas

  • ???subjectarea.asjc.3100.3105???
  • ???subjectarea.asjc.2600.2610???

قم بذكر هذا