Evaluation of henry's constant for h2s in water and sewage effluents

A. A. Al-Haddad, M. S.E. Abdo, Sabah A. Abdul-Wahab

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

9 اقتباسات (Scopus)

ملخص

An experimental set-up was used to evaluate Henry's constant (H) of H2S in distilled water and one of the sewage treatment plants in Kuwait. Calculated values of (H) for H2S in distilled water were found to agree with published works. For sewage, (H) was found to have a mean value of 601 atm/mole fraction for a temperature range of 20°C to 40°C. Factors affected the value of (H) in sewage were: initial concentration, flow rate of stripping fluid, pH, and pK. Effect of each factor was investigated and results were correlated. Copyright

اللغة الأصليةEnglish
الصفحات (من إلى)207-227
عدد الصفحات21
دوريةJournal of Environmental Science and Health.Part A: Environmental Science and Engineering
مستوى الصوت24
رقم الإصدار3
المعرِّفات الرقمية للأشياء
حالة النشرPublished - أبريل 1 1989
منشور خارجيًانعم

ASJC Scopus subject areas

  • ???subjectarea.asjc.2300.2310???

بصمة

أدرس بدقة موضوعات البحث “Evaluation of henry's constant for h2s in water and sewage effluents'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا