Comparison of HPLC and EMIT methods of cyclosporine assay in blood after bone marrow transplantation

B. Poonkuzhali, J. Victoria, R. Selvakumar, D. Dennison, A. Srivastava, L. Jeyaseelan, M. Chandy, A. S. Kanagasabapathy*

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

5 اقتباسات (Scopus)

ملخص

Cyclosporine (CsA) analysis in blood from patients who had undergone bone marrow transplantation for various haematological disorders was done both by high performance liquid chromatography (HPLC) and enzyme multiplied immunoassay technique (EMIT) and the results were compared. HPLC kit from Biorad Laboratories, USA, and EMIT kit from SYVA, UK, were used. The procedure for EMIT was slightly modified in-house to suit the Hitachi 704 discrete selective analyser. The CsA values obtained by these two methods correlated well within the therapeutic range (r value 0.96), HPLC method being most suitable outside the therapeutic range. Although HPLC is the ideal method for CsA, EMIT is quite suitable and can be adopted by any laboratory with an autoanalyser incorporating our modified procedure.

اللغة الأصليةEnglish
الصفحات (من إلى)39-41
عدد الصفحات3
دوريةIndian Journal of Medical Research
مستوى الصوت102
رقم الإصدارJULY
حالة النشرPublished - 1995
منشور خارجيًانعم

ASJC Scopus subject areas

  • ???subjectarea.asjc.1300.1300???

بصمة

أدرس بدقة موضوعات البحث “Comparison of HPLC and EMIT methods of cyclosporine assay in blood after bone marrow transplantation'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا