ملخص
A randomized controlled trial was conducted to compare the effectiveness of airflow-and waterflow-cooling blankets for febrile patients in intensive care unit. More patients in the airflow than in the waterflow-cooling blanket group reached the desired temperature of <38°C at the end of 8h (94·1 versus 60·0%, χ2=2·86, P=0·047). Patients in the airflow blanket group also took less time than those in the waterflow blanket group to achieve the desired temperature (3·1 and 5·7h, respectively, U=2·00, P<0·001). These findings suggest that the airflow blanket is the cooling blanket of choice for febrile patients when external cooling is needed.
اللغة الأصلية | English |
---|---|
الصفحات (من إلى) | 247-254 |
عدد الصفحات | 8 |
دورية | Nursing in critical care |
مستوى الصوت | 10 |
رقم الإصدار | 5 |
المعرِّفات الرقمية للأشياء | |
حالة النشر | Published - سبتمبر 2005 |
منشور خارجيًا | نعم |
ASJC Scopus subject areas
- ???subjectarea.asjc.2900.2906???