CMS RPC efficiency measurement using the tag-and-probe method

CMS Collaboration

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

1 اقتباس (Scopus)

ملخص

We measure the efficiency of CMS Resistive Plate Chamber (RPC) detectors in protonproton collisions at the centre-of-mass energy of 13 TeV using the tag-and-probe method. A muon from a Z0boson decay is selected as a probe of efficiency measurement, reconstructed using the CMS inner tracker and the rest of CMS muon systems. The overall efficiency of CMS RPC chambers during the 2016-2017 collision runs is measured to be more than 96% for the nominal RPC chambers.

اللغة الأصليةEnglish
رقم المقالC10020
دوريةJournal of Instrumentation
مستوى الصوت14
رقم الإصدار10
المعرِّفات الرقمية للأشياء
حالة النشرPublished - أكتوبر 2019

ASJC Scopus subject areas

  • ???subjectarea.asjc.3100.3105???
  • ???subjectarea.asjc.2600.2610???

قم بذكر هذا