CMS muon system phase 2 upgrade with triple-GEM detectors

D. Abbaneo, M. Abbas, M. Abbrescia, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, A. Aleksandrov, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. BenczeN. Beni, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, A. Braghieri, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F. R. Cavallo, A. Celik, M. Choi, S. Choi, J. Christiansen, A. Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, S. Czellar, M. M. Dabrowski, G. De Lentdecker, R. De Oliveira, G. De Robertis, S. Dildick, B. Dorney, G. Endroczi, F. Errico, A. Fenyvesi, S. Ferry, I. Furic, P. Giacomelli, J. Gilmore, V. Golovtsov, M. Gruchala, L. Guiducci, F. Guilloux, A. Gutierrez, R. M. Hadjiiska, J. Haus, K. Hoepfner, M. Hohlmann, H. Hoorani, P. Iaydjiev, Y. G. Jeng, T. Kamon, P. Karchin, A. Korytov, S. Krutelyov, A. Kumar, H. Kim, J. Lee, T. Lenzi, L. Litov, F. Loddo, A. Madorsky, T. Maerschalk, M. Maggi, A. Magnani, P. K. Mal, K. Mandal, A. Marchioro, A. Marinov, N. Majumdar, J. A. Merlin, G. Mitselmakher, A. K. Mohanty, A. Mohapatra, J. Molnar, S. Muhammad, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L. M. Pant, P. Paolucci, I. Park, G. Passeggio, B. Pavlov, B. Philipps, D. Piccolo, H. Postema, A. Puig Baranac, A. Radi, R. Radogna, G. Raffone, A. Ranieri, G. Rashevski, C. Riccardi, M. Rodozov, A. Rodrigues, L. Ropelewski, S. Roychowdhury, G. Ryu, M. S. Ryu, A. Safonov, S. Salva*, G. Saviano, A. Sharma, A. Sharma, R. Sharma, A. H. Shah, M. Shopova, J. Sturdy, G. Sultanov, S. K. Swain, Z. Szillasi, J. Talvitie, A. Tatarinov, T. Tuuva, M. Tytgat, I. Vai, M. Van Stenis, R. Venditti, E. Verhagen, P. Verwilligen, P. Vitulo, S. Volkov, A. Vorobyev, D. Wang, M. Wang, U. Yang, Y. Yang, R. Yonamine, N. Zaganidis, F. Zenoni, A. Zhang

*المؤلف المقابل لهذا العمل

نتاج البحث: Conference contribution

ملخص

The Compact Muon Solenoid (CMS) detector installed at the CERN Large Hadron Collider (LHC) has an extensive muon system which provides information simultaneously for identification, track reconstruction and triggering of muons. As a consequence of the extreme particle rate and high integrated charge, the essentiality to upgrade the LHC has given rise to the High Luminosity phase of the LHC (HL-LHC) project so that the CMS muon system will be upgraded with superior technological challenges. The CMS GEM collaboration offers a solution to equip the high-eta region of the muon system for Phase 2 (after the year 2017) with large-area triple-layer Gas Electron Multiplier (GEM) detectors, since GEMs have the ability to provide robust and redundant tracking and triggering functions with an excellent spatial resolution of order 100 micron and a high particle rate capability, with a close to 100% detection efficiency. In this contribution, the present status of the triple-GEM project will be reviewed, and the significant achievements from the start of the R&D in 2009 will be emphasized.

اللغة الأصليةEnglish
عنوان منشور المضيف2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
ناشرInstitute of Electrical and Electronics Engineers Inc.
رقم المعيار الدولي للكتب (الإلكتروني)9781467398626
المعرِّفات الرقمية للأشياء
حالة النشرPublished - أكتوبر 3 2016
منشور خارجيًانعم
الحدث2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015 - San Diego, United States
المدة: أكتوبر ٣١ ٢٠١٥نوفمبر ٧ ٢٠١٥

سلسلة المنشورات

الاسم2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015

Other

Other2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
الدولة/الإقليمUnited States
المدينةSan Diego
المدة١٠/٣١/١٥١١/٧/١٥

ASJC Scopus subject areas

  • ???subjectarea.asjc.3100.3106???
  • ???subjectarea.asjc.2700.2741???
  • ???subjectarea.asjc.3100.3105???

بصمة

أدرس بدقة موضوعات البحث “CMS muon system phase 2 upgrade with triple-GEM detectors'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا