Autogenous dermis-fat orbital impant for anophthalmic socket

Abdullah Al-Mujaini*, Anuradha Ganesh, Sana Al-Zuhaibi

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

7 اقتباسات (Scopus)

ملخص

To our knowledge, there is no report of dermis-fat graft (DFG) implant for orbital reconstruction from Oman. We hereby presented a case report of a 10-year-old boy with a blind and painful left eye secondary to penetrating eye injury presented with implant extrusion following evisceration with a polymethyl methacrylate implant. The evisceration procedure was converted to enucleation and a DFG orbital implant was then performed. Postoperatively, the graft was observed to be well integrated with the host orbital tissues and had good cosmetic and functional outcomes.

اللغة الأصليةEnglish
الصفحات (من إلى)145-148
عدد الصفحات4
دوريةSultan Qaboos University Medical Journal
مستوى الصوت7
رقم الإصدار2
حالة النشرPublished - أغسطس 2007