Arterial switch operation: Troponin T does not predict ventilation requirements

Madan M. Maddali*, John Valliattu, Taha al Delamie, Sunny Zacharias, Ahmed R. Ahmed, Shyam S. Ganguly

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

6 اقتباسات (Scopus)

ملخص

The aim of this study was to assess whether postoperative cardiac troponin T levels could predict ventilation requirements in infants undergoing the arterial switch operation. Cardiac troponin T was measured 6 hours after aortic cross clamping and prior to tracheal extubation in 20 consecutive patients; 10 had simple and 10 had complex (with ventricular septal defect) transposition of the great arteries. The mean plasma troponin T level prior to extubation did not differ significantly in patients who were re-intubated and those who were successfully extubated. The initial cardiac troponin T levels in the complex defect group was significantly higher than in the simple transposition group. There was no correlation between initial cardiac troponin T levels and the duration of mechanical ventilation. There was no difference in mean duration of ventilation between the 2 groups. It was concluded that the postoperative cardiac troponin T level is not a predictor of successful extubation or prolonged artificial ventilation in this subset.

اللغة الأصليةEnglish
الصفحات (من إلى)274-277
عدد الصفحات4
دوريةAsian Cardiovascular and Thoracic Annals
مستوى الصوت16
رقم الإصدار4
المعرِّفات الرقمية للأشياء
حالة النشرPublished - 2008

ASJC Scopus subject areas

  • ???subjectarea.asjc.2700.2746???
  • ???subjectarea.asjc.2700.2740???
  • ???subjectarea.asjc.2700.2705???

بصمة

أدرس بدقة موضوعات البحث “Arterial switch operation: Troponin T does not predict ventilation requirements'. فهما يشكلان معًا بصمة فريدة.